Fridge freezer: fridge warm, freezer fine
Cold air is not reaching the fridge. The fan has stopped, the flap has stuck shut, or the cooling coil has iced over because the defrost heater failed. A full manual defrost with the doors open may cure it for a few weeks; if it returns, that confirms a defrost fault.

Parts an engineer checks, in order
- Circulation fanAir
- Air flapAir
- Defrost heaterHeat
- Cooling coilCold
Safe to check yourself
Check the fridge setting. Open the freezer door, press the door switch and listen for the fan.
What to tell us
The temperature in each section and whether the freezer back panel is iced. Add the make, the full model number and your postcode.
American-style models, compressor replacement and sealed-system refrigerant work are outside our service.