Call 0800 037 4915

Fridge freezer repairs in Bexleyheath

Tell us which half is wrong, the temperature in each and the full model. Keep both doors shut where practical.

Engineer working at the base of a fridge freezer

Fridge freezer fault finder

Choose what the fridge freezer is doing. The parts most likely to be responsible light up, numbered in the order an engineer checks them.

  • Fridge sensorControl
  • Air flapAir
  • Circulation fanAir
  • Cooling coilCold
  • Defrost heaterHeat
  • Freezer sensorControl
  • Door sealsAir
  • DrainWater in
  • Compressor and relayMovement
  • Control boardControl
  • Control
  • Air
  • Cold
  • Heat
  • Water in
  • Movement

Fridge warm, freezer fine

Cold air is not reaching the fridge. The fan has stopped, the flap has stuck shut, or the cooling coil has iced over because the defrost heater failed. A full manual defrost with the doors open may cure it for a few weeks; if it returns, that confirms a defrost fault.

  1. Circulation fan
  2. Air flap
  3. Defrost heater
  4. Cooling coil

More on this fault and what to check

Both sections warm

If the lights work and nothing else does, listen at the back. Silence, a hum, or a click every few minutes each mean something different: the board, the compressor or its start relay.

  1. Compressor and relay
  2. Control board

More on this fault and what to check

Freezer warm, fridge fine

Less common, and more often found on models with separate cooling for each section. Check the freezer door and drawers are closing fully before anything else.

  1. Freezer sensor
  2. Door seals
  3. Cooling coil

More on this fault and what to check

Ice on the fridge back wall

A sheet of ice that never melts means the fridge is not cycling off. A door seal that lets damp air in, or a sensor reading warm, keeps it running.

  1. Fridge sensor
  2. Door seals
  3. Drain

More on this fault and what to check

Water in the fridge or on the floor

The fridge drain blocks, water pools under the salad drawer and finds its way down the front of the freezer door. It looks alarming and is usually the simplest fault to put right.

  1. Drain

More on this fault and what to check

Noisy

Ticking or scraping that stops when a door opens is a fan touching ice. Gurgles and cracks as the cabinet changes temperature are normal.

  1. Circulation fan
  2. Compressor and relay

More on this fault and what to check

American-style models, compressor replacement and sealed-system refrigerant work are outside our service.

What to tell us about your fridge freezer

In many frost-free fridge freezers all the cold is made in the freezer and a fan and flap share it with the fridge. That is why a warm fridge above a perfectly good freezer is the most common call of all, and why the two halves are reported separately.

Fridge freezer with both doors open in a family kitchen
Read what the film says

A fridge problem needs prompt attention. A Brassett assesses suitable conventional fridge and freezer repair enquiries. Send the model, observed temperature and full postcode. Keep doors closed where practical and arrange safe alternative food storage. American-style refrigeration, compressor replacement and refrigerant work are excluded. We check the fault and service scope before booking. Contact A Brassett for the next step.

Fridge freezer questions

Why is my fridge warm when the freezer is still frozen?

In a frost-free fridge freezer the fridge is cooled by air blown up from the freezer. When the fan, the flap or the defrost system fails, the freezer stays cold and the fridge warms up.

Should I defrost it before the engineer comes?

Only if we ask you to. A defrost can hide the evidence. Tell us what you see first.

Book a fridge freezer repair

Have the make, the model and your postcode to hand.

Call 0800 037 4915Book online